abflux_from_photom_keywords
- romanisim.image.abflux_from_photom_keywords(model, gain)
Get the electron rate of an AB source implied by an image’s photometric calibration.
L2 images are in DN / s, and the conversion to MJy / sr in meta.photometry.conversion_megajanskys contains a factor of the gain; see romanisim.util.update_photom_keywords. Given the gain, that conversion can be inverted to get the number of electron / s that the image’s calibration assigns to a source of one maggie; this is needed to get Poisson noise calculations correct. We therefore use this abflux computation in L2 source injection given a particular gain to get roughly the right Poisson noise while preserving the total fluxes consistently.
- Parameters:
- modelroman_datamodels.datamodels.ImageModel
model whose photometry keywords should be inverted
- gainfloat [electron / DN]
gain of the image
- Returns:
- abfluxfloat or None
electron / s corresponding to a source of one maggie, or None if the image lacks valid photometry keywords. The keywords are valid only if both the conversion and the pixel area are positive; this excludes placeholder values like the -999999 in fake data models.